Your waterfall stops and the control box displays Er6. Before ordering a new pump, you need to understand what this code indicates. For the AquaMax Eco Classic 9000 C, 12000 C and 18000 C covered by the OASE manual consulted, Er6 corresponds to dry running.
The priority is therefore to check the water supply. A pump installed in a pond may lack water if its intake is obstructed or if the level drops. And a so-called "dry" installation means that the motor is placed outside the pond: the pump must always receive water during operation.

Start with the exact reference and code
Take a photo of the screen before any handling. Also note the reference on the pump plate and that of the controller. The C suffix matters: advice from another AquaMax or an older control box is not necessarily applicable.
Read also:
Note when the message appears: at startup after winter, just after cleaning, after several hours of operation or when the pond level drops. This timeline gives a much more precise clue than the mere mention "the pump no longer works".
For example: if the incident immediately follows work on the pipes, first check what was moved. If the problem appears after several days of dropping water level, examine the water supply and the cause of this drop. These observations guide the diagnosis without proving, on their own, the origin of the failure.
Make the installation safe
Unplug the controller from the mains before intervening. Its stop button does not replace this disconnection. Before touching the water, disconnect the electrical equipment located in it. A pump whose cable or housing is damaged must not be put back into service.
Keep the controller out of the water. Perform only the maintenance operations provided for in the manual of your version. An abnormal smell, a damaged plug or an electrical trip requires professional inspection.
If the pump is submerged: examine the level and the water inlet
First observe the area where it works. The visible level near the terrace is not always the level of the technical compartment: a passage between two zones can be obstructed while the main pond seems sufficiently filled.
Read also:
After switching off, look if leaves, filaments or debris have accumulated around the intake. A local accumulation can be discreet from the bank. Fairly clear water on the surface does not allow you to conclude that the bottom is clean.
Photograph the layout before taking out the equipment. This reference prevents putting the pump back against a wall, in a hollow filled with sediment or under an element that hinders its supply. During reassembly, respect the complete immersion and the stable position provided by OASE.
If the level has dropped, also look for why: evaporation, leak, filter overflow or water sprayed outside. Adding water without monitoring its evolution can push back the next shutdown by just a few hours. A dated marker on the bank helps compare observations.
If the pump is installed out of the water: follow the intake circuit
Simply draw the path from the pond to the pump. Identify the valves, fittings, baskets and any pre-filters. This overview facilitates an orderly check and allows you to clearly describe the setup to an advisor.
- Was a valve left closed after maintenance?
- Was the hose bent, moved or compressed by an object?
- Is an accessible basket full of waste?
- Was a fitting dismantled just before the incident?
- Is the water supply maintained when the system starts?
These points are inspection leads for the circuit, not a list of guaranteed causes for every Er6. Have the priming and hydraulic layout confirmed if you do not know your installation. Multiplying tests on a poorly supplied circuit does not provide a reliable diagnosis.
A recent modification deserves special attention. Replacing a hose with a smaller diameter, adding fittings or moving the equipment changes the flow conditions. Keep the dimensions and photos to be able to assess these changes.
Clean what really hinders operation
Distinguish soft waste from limescale. Leaves and filaments are removed mechanically. For stubborn calcium deposits, OASE cites PumpClean in its manual. Dismantling, cleaning and reassembly must follow the document corresponding to the pump.
AquaActiv PumpClean 500 ml is an equipment maintenance product. Prepare the solution and respect the times indicated on its packaging; carefully rinse the elements before returning them to the circuit.

A targeted cleaning addresses an identified deposit. It does not repair a damaged component and does not restore a closed water inlet. If a part shows visible wear or damage, send its photo with the full reference before choosing its replacement.
The sludge returns around the pump: act also on the pond
A water inlet regularly buried under deposits reveals a need for broader maintenance. Look where the leaves arrive, how the waste circulates and which areas accumulate materials.
Read also: Choosing a pond pump: understanding flow rate, height and volume.
A PondoVac 4 vacuum cleaner allows you to remove deposits accessible by zones. This extraction must remain controlled: monitor the level during work and adapt the refilling to the needs of the pond.
Aquipond Bactovase can accompany the management of the organic fraction of sediments, according to its manual. Its action is part of the pond maintenance; Er6 first requires restoring the hydraulic supply of the pump.
A photo of the area after cleaning will serve as a comparison point. If the same accumulation quickly returns, reviewing the waste passage and the frequency of removal will be more useful than repeating the dismantling without any other change.
Prepare an observable restart
Once the cause is corrected and the assembly checked, follow the restart procedure of the manual. OASE indicates that the message resets after eliminating the fault.
Stay present to observe the return of water, the level in the compartments and the possible appearance of the code. Note the delay if the shutdown recurs. A few moments of operation is not enough to confirm that everything is back in order.
If Er6 persists, stop the tests and prepare the elements for the technical service. Changing several things at once makes the result difficult to interpret; a clear record of each intervention will help continue the diagnosis.
Protect the pond during the shutdown
Circulation participates in the operation of the filter and, according to the installation, in gas exchanges. During a prolonged failure, observe the fish and check the water quality. OATA notably recommends monitoring nitrogen compounds and maintaining an appropriate maintenance of the filtration.
An independent aeration, correctly dimensioned, can be useful. The AquaOxy 1000 is an example of equipment dedicated to this use; its choice depends on the pond and the population. It does not replace the mechanical and biological functions of the filter.
Avoid continuing abundant feeding while waste treatment is disturbed. If the fish breathe with difficulty or gather at the surface, water quality and oxygenation become priorities: quickly ask for appropriate advice.
The information to transmit to obtain precise help
| To prepare | Why it is useful |
|---|---|
| Photos of the plates and the screen | Identify the version and the exact message. |
| View of the pond and the circuit | Understand the water inlet and the assembly. |
| Date and circumstances of the first shutdown | Link the incident to an eventual change. |
| Checks and cleanings already performed | Continue the diagnosis without repeating the same tests. |
Choose the maintenance adapted to your pump
Start by identifying the cause of the shutdown. If the check reveals limescale on the elements concerned, consult the indications of the recommended cleaner and the manual of your pump.
Sources
- OASE — AquaMax Eco Classic 9000 C / 12000 C / 18000 C Manual, French sections on errors, installation and maintenance.
- OATA — How to look after pond fish : water monitoring and filtration.
- OASE — Calculate the total dynamic head : influence of the hydraulic circuit.
- Aquishop sheets of the products related in the article: PumpClean, PondoVac 4, Aquipond Bactovase and AquaOxy 1000.